Skip to main navigation Skip to search Skip to main content

A multisite assessment of the quantitative capabilities of the Xpert MTB/RIF assay

  • Robert Blakemore
  • , Pamela Nabeta
  • , Amy L. Davidow
  • , Viral Vadwai
  • , Rasim Tahirli
  • , Vanisha Munsamy
  • , Mark Nicol
  • , Martin Jones
  • , David H. Persing
  • , Doris Hillemann
  • , Sabine Ruesch-Gerdes
  • , Felicity Leisegang
  • , Carlos Zamudio
  • , Camilla Rodrigues
  • , Catharina C. Boehme
  • , Mark D. Perkins
  • , David Alland
  • University of Medicine and Dentistry of New Jersey
  • Foundation for Innovative New Diagnostics (FIND)
  • University of Medicine and Dentistry of New Jersey
  • P.D. Hinduja Hospital and Medical Research Centre
  • Special Treatment Institution for Detainees with Tuberculosis
  • South African Medical Research Council
  • University of Cape Town
  • Cepheid
  • Research Center Borstel

Research output: Contribution to journalArticlepeer-review

112 Scopus citations

Abstract

Rationale: The Xpert MTB/RIF is an automated molecular test for Mycobacterium tuberculosis that estimates bacterial burden by measuring the threshold-cycle (Ct) of its M. tuberculosis-specific real-time polymerase chain reaction. Bacterialburden is an important biomarker for disease severity, infection control risk, and response to therapy. Objectives: Evaluate bacterial load quantitation by Xpert MTB/RIF compared with conventional quantitative methods. Methods: Xpert MTB/RIF results we recompared with smear-microscopy, semiquantiative solid culture, and time-to-detection in liquid culture for 741 patients and 2,008 samples tested in a multisite clinical trial. An internal control real-time polymerase chain reaction was evaluated for its ability to identify inaccurate quantitative Xpert MTB/RIF results. Measurements and Main Results: Assays with an internal control Ct greater than 34 were likely to be inaccurately quantitated; this represented 15% of M. tuberculosis-positive tests. Excluding these, decreasing M. tuberculosis Ct was associated with increasing smear microscopy grade for smears of concentrated sputum pellets (r s = 20.77) and directly from sputum (r s = -0.71). A Ct cutoff of approximately 27.7 best predicted smear-positive status. The association between M. tuberculosis Ct and time-to-detection in liquid culture (r s = 0.68) andsemiquantitative colony counts (r s = -0.56)wasweaker than smear. Tests of paired same-patient sputum showed that highviscosity sputum samples contained x32 more M. tuberculosis than nonviscous samples. Comparisons between the grade of the acid-fast bacilli smear and Xpert MTB/RIF quantitative data across study sites enabled us to identify a site outlier inmicroscopy. Conclusions: Xpert MTB/RIF quantitation offers a new, standardized approach to measuring bacterial burden in the sputum of patients with tuberculosis.

Original languageEnglish
Pages (from-to)1076-1084
Number of pages9
JournalAmerican Journal of Respiratory and Critical Care Medicine
Volume184
Issue number9
DOIs
StatePublished - 1 Nov 2011

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Clinical trial
  • Diagnosis
  • Diagnostic techniques and procedures
  • Molecular diagnostics
  • Tuberculosis

Fingerprint

Dive into the research topics of 'A multisite assessment of the quantitative capabilities of the Xpert MTB/RIF assay'. Together they form a unique fingerprint.

Cite this