Skip to main navigation Skip to search Skip to main content

Measurement of intraocular pressure using rebound tonometry in anesthetized free-ranging South American sea lions (Otaria byronia)

  • Brookfield Zoo
  • University of Illinois Urbana-Champaign
  • Denver Zoo

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Intraocular pressures (IOPs) were measured using a rebound tonometer in 56 free-ranging adult South American sea lions (Otaria byronia) from Punta San Juan, Peru. All animals were anesthetized using medetomidine, midazolam, and butorphanol and determined to be in good health. No ocular abnormalities were observed affecting the cornea or ocular adnexa. Field conditions precluded evaluation of the lens and posterior segment of the eye. Mean (SD) IOP values for males (n¼37) were 31±11 mmHg (right eye) and 31±9 mmHg (left eye). The same values for females (n¼19) were 24±9 mmHg in the left eye and 27±10 mmHg in the right eye. These values are similar to those previously reported for pinnipeds under professional care and higher than those generally reported for terrestrial mammals.

Original languageEnglish
Pages (from-to)885-888
Number of pages4
JournalJournal of Wildlife Diseases
Volume55
Issue number4
DOIs
StatePublished - Oct 2019

Keywords

  • Intraocular pressure
  • Otaria byronia
  • Pinniped
  • Rebound tonometry
  • South American sea lion
  • TonoVet

Fingerprint

Dive into the research topics of 'Measurement of intraocular pressure using rebound tonometry in anesthetized free-ranging South American sea lions (Otaria byronia)'. Together they form a unique fingerprint.