Comparison of next-generation portable pollution monitors to measure exposure to PM2.5 from household air pollution in Puno, Peru

  • HAPIN Investigators
  • Johns Hopkins University School of Medicine
  • Johns Hopkins Bloomberg School of Public Health
  • Berkeley Air Monitoring Group
  • University of California, Berkeley
  • Rollins School of Public Health
  • Johns Hopkins University
  • Swiss Tropical and Public Health Institute Swiss TPH
  • University of Georgia
  • Colorado State University

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

17 Citas (Scopus)

Resumen

Assessment of personal exposure to PM2.5 is critical for understanding intervention effectiveness and exposure-response relationships in household air pollution studies. In this pilot study, we compared PM2.5 concentrations obtained from two next-generation personal exposure monitors (the Enhanced Children MicroPEM or ECM; and the Ultrasonic Personal Air Sampler or UPAS) to those obtained with a traditional Triplex Cyclone and SKC Air Pump (a gravimetric cyclone/pump sampler). We co-located cyclone/pumps with an ECM and UPAS to obtain 24-hour kitchen concentrations and personal exposure measurements. We measured Spearmen correlations and evaluated agreement using the Bland-Altman method. We obtained 215 filters from 72 ECM and 71 UPAS co-locations. Overall, the ECM and the UPAS had similar correlation (ECM ρ = 0.91 vs UPAS ρ = 0.88) and agreement (ECM mean difference of 121.7 µg/m3 vs UPAS mean difference of 93.9 µg/m3) with overlapping confidence intervals when compared against the cyclone/pump. When adjusted for the limit of detection, agreement between the devices and the cyclone/pump was also similar for all samples (ECM mean difference of 68.8 µg/m3 vs UPAS mean difference of 65.4 µg/m3) and personal exposure samples (ECM mean difference of −3.8 µg/m3 vs UPAS mean difference of −12.9 µg/m3). Both the ECM and UPAS produced comparable measurements when compared against a cyclone/pump setup.

Idioma originalInglés
Páginas (desde-hasta)445-458
Número de páginas14
PublicaciónIndoor Air
Volumen30
N.º3
DOI
EstadoPublicada - 1 may. 2020

ODS de las Naciones Unidas

Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

  1. ODS 3: Salud y bienestar
    ODS 3: Salud y bienestar

Huella

Profundice en los temas de investigación de 'Comparison of next-generation portable pollution monitors to measure exposure to PM2.5 from household air pollution in Puno, Peru'. En conjunto forman una huella única.